3P, 40 FLA/50A Max 24V AC CONTACTOR : AFTC-CTN-117
This model maintains the heavy-duty 3-Phase power handling of the previous unit but introduces a critical change in coil voltage, shifting to low-voltage automation control.
📋 Technical Specifications
- Model Number:
AFTC-CTN-117 - Number of Poles: 3P (Three-pole configuration for three-phase systems)
- Current Rating: 40 FLA (Full Load Amps) / 50A Max resistive load per pole.
- Control Coil Voltage: 24V AC at 50/60 Hz (⚠️ Crucial change: This unit uses a low-voltage 24V control signal instead of line voltage, making it directly compatible with standard HVAC thermostats and 24V step-down transformers).
- Standard Compliance:
IEC60947
⚡ Horsepower & Load Breakdown
The faceplate details the power handling limits based on operating voltage:
- At 240V AC: Handles up to 240 LRA (Locked Rotor Amps).
- 1-Phase Power: Rated up to 7.5 HP (Horsepower).
- 3-Phase Power: Rated up to 15 HP.
- At 480V / 600V AC: Handles up to 180/150 LRA.
- 3-Phase Power: Rated up to 25 HP.
- At 120V AC:
- 1-Phase Power: Rated up to 3 HP.
📞 Contact & Procurement Details
To secure pricing, check stock availability, or coordinate bulk fulfillment across Saudi Arabia, contact the Ayub First Trading Company distribution offices directly:
- Primary Hotline (Call/WhatsApp): +966 56 004 2170
- Email Inquiries: ayubfirsttrading@gmail.com
- Corporate Web Platform: ayubfirsttrading.com
- Regional Warehouses: Showrooms fully stocked in Riyadh (Al Jabrah, Batha Road), Jeddah, Dammam, and Al Khobar (20th Street, Hail Road).
Description
Description
This model maintains the heavy-duty 3-Phase power handling of the previous unit but introduces a critical change in coil voltage, shifting to low-voltage automation control.
📋 Technical Specifications
- Model Number:
AFTC-CTN-117 - Number of Poles: 3P (Three-pole configuration for three-phase systems)
- Current Rating: 40 FLA (Full Load Amps) / 50A Max resistive load per pole.
- Control Coil Voltage: 24V AC at 50/60 Hz (⚠️ Crucial change: This unit uses a low-voltage 24V control signal instead of line voltage, making it directly compatible with standard HVAC thermostats and 24V step-down transformers).
- Standard Compliance:
IEC60947
⚡ Horsepower & Load Breakdown
The faceplate details the power handling limits based on operating voltage:
- At 240V AC: Handles up to 240 LRA (Locked Rotor Amps).
- 1-Phase Power: Rated up to 7.5 HP (Horsepower).
- 3-Phase Power: Rated up to 15 HP.
- At 480V / 600V AC: Handles up to 180/150 LRA.
- 3-Phase Power: Rated up to 25 HP.
- At 120V AC:
- 1-Phase Power: Rated up to 3 HP.
📞 Contact & Procurement Details
To secure pricing, check stock availability, or coordinate bulk fulfillment across Saudi Arabia, contact the Ayub First Trading Company distribution offices directly:
- Primary Hotline (Call/WhatsApp): +966 56 004 2170
- Email Inquiries: ayubfirsttrading@gmail.com
- Corporate Web Platform: ayubfirsttrading.com
- Regional Warehouses: Showrooms fully stocked in Riyadh (Al Jabrah, Batha Road), Jeddah, Dammam, and Al Khobar (20th Street, Hail Road).
Be the first to review “3P, 40 FLA/50A Max 24V AC CONTACTOR : AFTC-CTN-117” Cancel reply

Reviews
There are no reviews yet.